  1. What is the purpose of the concentric neutral on SE cable ...

    Aug 7, 2023 · Why is it beneficial to have the neutral (concentric neutral) on SE cable wrapping around the other cables? Safety feature? Decreases electromagnetic interference?

  2. Using MV cable concentric neutral for Equipment Ground Conductor …

    Nov 5, 2024 · Can a concentric neutral that is part of an MV cable shield be used to satisfy the equipment grounding conductor (EGC) requirement per NEC 250.122? For example can a cable with …

  3. Concentric Neutral and NEC | Information by Electrical Professionals ...

    Apr 11, 2016 · If concentric neutral cables aren't NEC compliant to be used as a neutral, then I don't see any way for the conduits to be re-used. I was thinking I could use type MV-90 cable and split the …

  4. Concentric Neutral vs Copper Tape | Information by Electrical ...

    Oct 28, 2020 · If there are no line to neutral loads, the concentric neutral can be used as the required equipment grounding conductor. A cable with a tape shield will always require a separate equipment …

  5. Submittal Reviews: Concentric Neutral and URD/UD

    Mar 14, 2013 · As for the 100% VS 1/3 neutral you are getting basically a larger neutral conductor. All I can find defining the difference between URD and UD Is Okonite lists URD as Underground …

  6. Grounding of Concentric Neutral (or tape shield) Cable on a Delta MV ...

    Jan 26, 2015 · Does one ground the concentric neutral or tape shield of the MV wire to earth in this case, or must it be isolated and then grounded when the circuit is opened?

  7. medium voltage cable question? | Information by Electrical ...

    Jul 19, 2007 · The concentric wires can be rated anywhere from 1/3 the capacity of the cables conductor up to 100%. SCE used to use unjacketed concentric neutral cable but recently changed to jacketed. …

  8. 1/3 nuetral versus full nuetral | Information by Electrical ...

    Apr 23, 2004 · Re: 1/3 nuetral versus full nuetral I've seen 1/3 concentric neutrals for URD cable for primary utility power. Our POCO requires 100% concentric neutrals even for 3 phase services. If …

  9. 15KV MV cable shield ground conductor size | Information by Electrical ...

    Oct 26, 2020 · I cant seem to find any standard directly related to shield grounding size in medium voltage applications. I curious as to what your calling “shield”. Is it tape shield, or the 14awg …

  10. Current on a 34.5kv Concentric Neutral - Mike Holt's Forum

    Oct 9, 2023 · The substation transformer concentric neutral will be tied to the center-point of each distribution transformers wye center point. This will create an opportunity for circulating ground …